FXUQ100AVEB |
FXUQ100AVEB9 |
FXUQ71AVEB |
FXUQ71AVEB9 |
Sound pressure level
|
Heating
|
At high fan speed
|
dBA
|
47.0
|
47.0
|
40.0
|
40.0
|
|
|
At low fan speed
|
dBA
|
40.0
|
40.0
|
36.0
|
36.0
|
|
|
At medium fan speed
|
dBA
|
44.0
|
44.0
|
38.0
|
38.0
|
|
Cooling
|
At low fan speed
|
dBA
|
40.0
|
40.0
|
36.0
|
36.0
|
|
|
At high fan speed
|
dBA
|
47.0
|
47.0
|
40.0
|
40.0
|
|
|
At medium fan speed
|
dBA
|
44.0
|
44.0
|
38.0
|
38.0
|
Standard Accessories
|
Operation manual
|
Operation manual
|
Operation manual
|
Operation manual
|
Operation manual
|
|
Installation manual
|
Installation manual
|
Installation manual
|
Installation manual
|
Installation manual
|
|
Declaration of conformity
|
Declaration of conformity
|
Declaration of conformity
|
Declaration of conformity
|
Declaration of conformity
|
|
Drain hose
|
Drain hose
|
Drain hose
|
Drain hose
|
Drain hose
|
|
Clamp metal
|
Clamp metal
|
Clamp metal
|
Clamp metal
|
Clamp metal
|
|
Washer for hanger bracket
|
Washer for hanger bracket
|
Washer for hanger bracket
|
Washer for hanger bracket
|
Washer for hanger bracket
|
|
Clamps
|
Clamps
|
Clamps
|
Clamps
|
Clamps
|
|
Washer clamp
|
Washer clamp
|
Washer clamp
|
Washer clamp
|
Washer clamp
|
|
Joint insulating material
|
Joint insulating material
|
Joint insulating material
|
Joint insulating material
|
Joint insulating material
|
|
Sealing material
|
Sealing material
|
Sealing material
|
Sealing material
|
Sealing material
|
|
Elbow
|
Elbow
|
Elbow
|
Elbow
|
Elbow
|
|
Installation pattern
|
Installation pattern
|
Installation pattern
|
Installation pattern
|
Installation pattern
|
|
Blocking material
|
Blocking material
|
Blocking material
|
Blocking material
|
Blocking material
|
|
L-bent piping
|
L-bent piping
|
L-bent piping
|
L-bent piping
|
L-bent piping
|
|
Screws
|
Screws
|
Screws
|
Screws
|
Screws
|
|
Non woven fabric
|
Non woven fabric
|
Non woven fabric
|
Non woven fabric
|
Non woven fabric
|
Refrigerant
|
GWP
|
|
2,087.5
|
2,087.5
|
2,087.5
|
2,087.5
|
|
Type
|
|
R-410A
|
R-410A
|
R-410A
|
R-410A
|
Power input - 50Hz
|
Cooling
|
At high fan speed
|
kW
|
0.200
|
0.200
|
0.090
|
0.090
|
|
Heating
|
At high fan speed
|
kW
|
0.179
|
0.179
|
0.073
|
0.073
|
Cooling capacity
|
Total capacity
|
At high fan speed
|
kW
|
11.2
|
11.2
|
8.0
|
8.0
|
Piping connections
|
Liquid
|
OD
|
mm
|
9.52
|
9.5
|
9.52
|
9.5
|
|
|
Type
|
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
|
Gas
|
OD
|
mm
|
15.9
|
15.9
|
15.9
|
15.9
|
|
|
Type
|
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
|
Drain
|
|
I.D. 20/O.D. 26
|
I.D. 20/O.D. 26
|
I.D. 20/O.D. 26
|
I.D. 20/O.D. 26
|
Sound power level
|
Cooling
|
At high fan speed
|
dBA
|
65
|
65
|
58
|
58
|
Air filter
|
Type
|
|
Resin net with mold resistance
|
Resin net with mold resistance
|
Resin net with mold resistance
|
Resin net with mold resistance
|
Dimensions
|
Unit
|
Width
|
mm
|
950
|
950
|
950
|
950
|
|
|
Depth
|
mm
|
950
|
950
|
950
|
950
|
|
|
Height
|
mm
|
198
|
198
|
198
|
198
|
Casing
|
Material
|
|
Resin
|
Resin
|
Resin
|
Resin
|
|
Colour
|
|
Fresh White
|
Fresh White
|
Fresh White
|
Fresh White
|
Weight
|
Unit
|
kg
|
27
|
27
|
26
|
26
|
Fan
|
Air flow rate - 50Hz
|
Cooling
|
At high fan speed
|
m³/min
|
31.0
|
31.0
|
22.5
|
22.5
|
|
|
|
At low fan speed
|
m³/min
|
21.0
|
21.0
|
16.0
|
16.0
|
Heating capacity
|
Total capacity
|
At high fan speed
|
kW
|
12.5
|
12.5
|
9.0
|
9.0
|
Current - 50Hz
|
Maximum fuse amps (MFA)
|
A
|
16
|
16
|
16
|
16
|
Power supply
|
Phase
|
|
1~
|
1~
|
1~
|
1~
|
|
Frequency
|
Hz
|
50/60
|
50/60
|
50/60
|
50/60
|
|
Voltage
|
V
|
220-240/220-230
|
220-240/220-230
|
220-240/220-230
|
220-240/220-230
|
Notes
|
(1) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
(1) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
(1) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
(1) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
|
(2) - Maximum allowable voltage range variation between phases is 2%.
|
(2) - Maximum allowable voltage range variation between phases is 2%.
|
(2) - Maximum allowable voltage range variation between phases is 2%.
|
(2) - Maximum allowable voltage range variation between phases is 2%.
|
|
(3) - MCA/MFA: MCA = 1.25 x FLA
|
(3) - MCA/MFA: MCA = 1.25 x FLA
|
(3) - MCA/MFA: MCA = 1.25 x FLA
|
(3) - MCA/MFA: MCA = 1.25 x FLA
|
|
(4) - MFA ≤ 4 x FLA
|
(4) - MFA ≤ 4 x FLA
|
(4) - MFA ≤ 4 x FLA
|
(4) - MFA ≤ 4 x FLA
|
|
(5) - Next lower standard fuse rating minimum 16A
|
(5) - Next lower standard fuse rating minimum 16A
|
(5) - Next lower standard fuse rating minimum 16A
|
(5) - Next lower standard fuse rating minimum 16A
|
|
(6) - Select wire size based on the value of MCA
|
(6) - Select wire size based on the value of MCA
|
(6) - Select wire size based on the value of MCA
|
(6) - Select wire size based on the value of MCA
|
|
(7) - Instead of a fuse, use a circuit breaker
|
(7) - Instead of a fuse, use a circuit breaker
|
(7) - Instead of a fuse, use a circuit breaker
|
(7) - Instead of a fuse, use a circuit breaker
|
|
(8) - Contains fluorinated greenhouse gases
|
(8) - Contains fluorinated greenhouse gases
|
(8) - Contains fluorinated greenhouse gases
|
(8) - Contains fluorinated greenhouse gases
|